OVI (20mA) | OVI (30mA) | ACS | DCC | DDD (128K) | DDD (64K) | DVI (200mA) | DVI (300mA) | DVI (2K) | MUX | HVS | OFS | PRO | PV3 | PV2 | PV1 | TMU | LZB | OAL | DVI (2000mA) |

BOARDS INVENTORY (HVS) (click on serial number to view details)
BOARD NAMEPART NUMBERREV.SERIAL NUMBERCUSTOMER NAMELOCATIONCATEGORYSTATUSPRIORITY
FAILURE MODE
REPAIR DURATION
START REPAIREND REPAIRREPAIR COUNTDOWNHISTORYDEFECTIVE DATEREPAIRED BYREPAIRED DATE
HVSC370054BECCIBECCI-BRGDEFECTIVEACTIVETOP PRIORITY
HARD/GROSS
1 month
--- failed on all diagnostic tests.
--- lacking parts.
--- for checking and ohming.
failed before 2011
HVSC370066BECCIBECCI-PRODUCTIONGOODACTIVE
HVSC370027BECCIBECCI-BRGDEFECTIVEACTIVETOP PRIORITY
HARD/GROSS
1 month
--- failed on all diagnostic tests.
--- open trace problem.
failed before 2011
HVSA370070BECCIBECCI-BRGDEFECTIVEACTIVETOP PRIORITY
HARD/GROSS
2 month
--- failed on all diagnostic tests.
--- open trace problem.
--- for further ohming.
May 15, 2012
HVSA370017BECCIBECCI-PRODUCTIONGOODACTIVE
HVSF370190BECCIUSEAGOODACTIVE
HVSB370025BECCIBECCI-PRODUCTIONGOODACTIVE--- failed on all diagnostic tests.
--- for ohming and component checking.
HVSF307211BECCIBECCI-PRODUCTIONGOODACTIVE
HVSF370236BECCIUSEAGOODACTIVE* Failed on all diagnostic test.

Shipped to USEA.
Attention: Maverick Castro
Jan. 2013

* Corrective Action:
--- Replaced U14 (LF4112CN). Passed Diagnostic test. Oct. 17, 2012
Sept. 2012Adrian De LeonOct. 17, 2012
HVSA307213BECCIUSEAGOODACTIVE* failed on calibration @ QM1000 tester (TMT11).
- Intermediate Failure (2 weeks).

Corrective Action :
- Replaced U33, U36, U32 (lF412CN) and Q3 (IRF9530).
- Passed all diagnoatic @ higher ASL version. 9/27/12

Shipped to USEA.
Attention: Maverick Castro
Jan. 2013
July. 24, 2012.Adrian De LeonSeptember 27, 2012
HVSB370014BECCIBECCI-PRODUCTIONGOODACTIVE
HVSA370682BECCIBECCI-PRODUCTIONGOODACTIVE
HVSA370031BECCIBECCI-PRODUCTIONGOODACTIVE
HVSa370019BECCIBECCI-BRGGOODACTIVE
HVSA370196BECCIUSEAGOODACTIVE
HVSF370047BECCIBECCI-PRODUCTIONGOODACTIVE